Car Gear Picks

Pt100 Temperature Sensor Buying Guide

A Pt100 temperature sensor is a platinum resistance thermometer (RTD) that reads 100 Ω at 0 °C and changes resistance predictably with heat, used in industrial, HVAC, and process control loops. The primary trade-off is between thin-film elements (fast, compact, lower cost, drift-prone above ~400 °C) and wire-wound elements (slower, larger, higher stability up to 600 °C+). The clear decision rule: buy a 3-wire or 4-wire Class A/B probe matched to your controller's input type and cable environment; skip 2-wire probes and unclassified elements for any measurement where ±0.5 °C accuracy matters.

Element Type:Thin-film vs wire-wound Pt100Accuracy Class:Class A (±0.15 °C) / Class B (±0.30 °C)Wiring Config:2-wire / 3-wire / 4-wireSheath & Insulation:304/316 SS; PVC / PTFE / fiberglass

At a glance

Price range
Price range not synced yet
Category
Electrical, Sensors & Switches
Data updated
Nov 15, 2026

Current offers

No verified match right now. Browse live listings:

Highlights

  • Pt100 element types differ by construction: thin-film RTDs suit compact probes and fast response below 400 °C; wire-wound RTDs deliver tighter long-term stability at 400–600 °C.
  • Accuracy classes define real tolerance: Class A (±0.15 °C at 0 °C) vs Class B (±0.30 °C at 0 °C) — Class A is the minimum for calibration-adjacent work.
  • Wiring count changes accuracy: 3-wire compensates lead resistance for most industrial transmitters; 4-wire eliminates lead error entirely for high-precision data logging.
  • Sheath and cable materials determine survival: 304/316 stainless steel sheaths for general use; PTFE or fiberglass insulation for >150 °C or chemical exposure; PVC only for benign, low-temp runs.

Best use cases

  • Pick a 3-wire Class A thin-film probe with 316 stainless sheath and PTFE cable for HVAC duct, boiler, or food-service monitoring where ±0.3 °C accuracy and moisture resistance matter.
  • Choose a 4-wire wire-wound Class A probe with mineral-insulated (MI) cable for laboratory baths, calibration references, or process lines above 400 °C where lead resistance and drift must be negligible.
  • Skip 2-wire unclassified probes for any controller expecting Pt100 input — lead resistance in long runs alone can add several degrees of error; reserve them only for short, non-critical indication.
  • For embedded OEM designs or tight panel enclosures, select a bare thin-film element or M12-connector probe rather than a full stainless assembly; avoid long rigid sheaths where vibration or bend radius is limited.

Buying tips

  • Match probe wiring to your transmitter or PLC input: 3-wire for standard industrial transmitters, 4-wire for precision meters — a 2-wire probe mated to a 3-wire input leaves accuracy on the table.
  • Use the Pt100 resistance curve: 100 Ω at 0 °C, ~138.5 Ω at 100 °C, ~175.9 Ω at 200 °C — verify your controller's excitation current and range before ordering.
  • Select sheath diameter and length by response time and immersion: 3–6 mm sheaths respond faster; ensure immersion depth is at least 10× sheath diameter for accurate readings.
  • Choose insulation by environment: PVC cable below 105 °C, PTFE or fiberglass above 150 °C, and stainless braid over cable in abrasion or washdown areas.

Specs

Element TypeThin-film vs wire-wound Pt100
Accuracy ClassClass A (±0.15 °C) / Class B (±0.30 °C)
Wiring Config2-wire / 3-wire / 4-wire
Sheath & Insulation304/316 SS; PVC / PTFE / fiberglass

Related searches

What to check before buying

  • Measure your process connection: thread size (G1/2, 1/4 NPT, M12), insertion length, and whether a thermowell is required for pressurized or corrosive lines.
  • Confirm controller input compatibility: Pt100 vs Pt1000, 2/3/4-wire mode, and temperature range — a Pt100 probe on a Pt1000-only input reads roughly 10× low.
  • Check environment ratings: IP65/IP67 for washdown, chemical compatibility of wetted parts, and maximum ambient temperature at the terminal head.
  • Verify cable run length and routing: long runs favor 4-wire or a local transmitter; avoid routing RTD leads parallel to mains or VFD cabling without shielding.

FAQ

All Electrical, Sensors & Switches buying guides

Data sources: eBay / Amazon listings and product attribute feeds Data updated Nov 15, 2026.

Some links on this page are affiliate links. If you buy after clicking one, we may earn a commission at no extra cost to you. This does not change which products appear here or their order. Affiliate disclosure.